Search results for "selected ion monitoring"

showing 10 items of 19 documents

The Ramsey method in high-precision mass spectrometry with Penning traps: Experimental results

2007

The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external radiofrequency-quadrupole fields. In this work a new excitation scheme, Ramsey's method of time-separated oscillatory fields, has been successfully tested. It has been shown to reduce significantly the uncertainty in the determination of the cyclotron frequency and thus of the ion mass of interest. The theoretical description of the ion motion excited with Ramsey's method in a Penning trap and subsequently the calculation of the resonance line shapes for differ…

ChemistryAtomic Physics (physics.atom-ph)Other Fields of PhysicsFOS: Physical sciencesCondensed Matter PhysicsPenning trapMass spectrometryISOLTRAPFourier transform ion cyclotron resonancePhysics - Atomic PhysicsGeneral Physics (physics.gen-ph)Physics - General PhysicsSelected ion monitoringIon trapPhysical and Theoretical ChemistryQuadrupole ion trapAtomic physicsInstrumentationSpectroscopyExcitation
researchProduct

Excitation and detection geometries for Fourier-transform mass spectometry

1994

A short overview of current excitation and detection techniques for Fourier-transform mass spectrometry and related ion cyclotron resonance experiments is given, and some ideas are discussed which may lead to new developments.

ChemistryOrganic ChemistryAnalytical chemistryMass spectrometryFourier transform ion cyclotron resonanceFourier transform spectroscopyAnalytical ChemistryComputational physicsIonsymbols.namesakeFourier transformPhysics::Plasma PhysicssymbolsSelected ion monitoringSpectroscopyExcitationIon cyclotron resonanceRapid Communications in Mass Spectrometry
researchProduct

First Fourier-transform ion cyclotron resonance signals of very highly charged atomic ions

1994

We report on the first application of Fourier-transform ion cyclotron resonance mass spectrometry to the very highly charged ions produced in the high-energy electron beam ion trap (SuperEBIT) at the Lawrence Livermore National Laboratory. Initial results are described, and spectra are presented from ions as highly charged as Cs53+.

ChemistryOrganic ChemistryAnalytical chemistryMass spectrometryFourier transform ion cyclotron resonanceSpectral lineAnalytical ChemistryIonPhysics::Plasma PhysicsSelected ion monitoringIon trapAtomic physicsSpectroscopyIon cyclotron resonanceElectron beam ion trapRapid Communications in Mass Spectrometry
researchProduct

High Resolution Mass Spectrometry of Light Ions in a Penning Trap

1996

ChemistryOrganic ChemistryAnalytical chemistrySelected ion monitoringIon trapPenning trapMass spectrometrySpectroscopyIon cyclotron resonanceFourier transform ion cyclotron resonanceAnalytical ChemistryIonRapid Communications in Mass Spectrometry
researchProduct

Properties and performance of a quadrupole mass filter used for resonance ionization mass spectrometry

1998

Abstract The performance of commercial quadrupole mass spectrometers (QMS) with a number of imperfections, as compared to the ideal hyperbolic geometry, has been characterized using the computer simulation program simion 3d version 6.0. The analysis of simulated QMS geometries focuses primarily on modeling of the internal potential, the study of field deviations, and the influence of finite length on performance of the QMS. The computer simulation of ion trajectories in the QMS field yields predictions for optimum working conditions and provides estimates for the resolving power and the maximum isotopic abundance sensitivity. Experimental measurements that confirm these expectations are pre…

ChemistrySelected reaction monitoringAnalytical chemistryThermal ionization mass spectrometryCondensed Matter PhysicsMass spectrometryTriple quadrupole mass spectrometerComputational physicsSelected ion monitoringPhysical and Theoretical ChemistryTime-of-flight mass spectrometryInstrumentationQuadrupole mass analyzerSpectroscopyHybrid mass spectrometerInternational Journal of Mass Spectrometry
researchProduct

Polychlorinated phenols and their metabolites in soil and earthworms of sawmill environment

1990

Abstract Topsoil and earthworm samples collected from three Finnish sawmill environments were analysed for polychlorinated phenols, 2,3,4,6-tetrachloro- and pentachlorophenol, and their metabolites. Analyses were carried out by gas chromatography/mass spectrometry using a selected ion monitoring technique and by dual-channel gas chromatography using quartz capillary columns and two electron capture detectors. The total chlorophenol concentrations ranged from ca. 260 to 480 μg/g (dry weight) in soil and from ca. 140 to 3500 μg/g fat in earthworms. The most important metabolites in soil were chlorinated dihydroxy-benzenes (also at ppm level); only traces of chlorinated anisoles were detected …

ChlorophenolTopsoilEnvironmental EngineeringChromatographybiologyHealth Toxicology and MutagenesisEarthwormPublic Health Environmental and Occupational HealthGeneral MedicineGeneral Chemistrybiology.organism_classificationPollutionSoil contaminationPentachlorophenolchemistry.chemical_compoundchemistryDry weightEnvironmental chemistryEnvironmental ChemistrySelected ion monitoringGas chromatographyChemosphere
researchProduct

Analysis of organophosphorus pesticides in honeybee by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

2001

Pesticides applied in extended agricultural fields may be controlled by means of bioindicators, such as honeybees, in which are the pesticides bioaccumulate. Liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) experiments with positive (PI) and negative (NI) ion modes were optimized for the analysis of 22 organophosphorus pesticides in honeybee samples. The extraction required 3 g of sample, which was extracted with acetone. The extract was purified with coagulating solution and reextracted with Cl(2)CH(2). Pesticides studied could be detected by both ionization modes except for parathion, parathion-methyl, and bromophos, which did not give signals …

Detection limitChemical ionizationInsecticidesChromatographyExtraction (chemistry)Analytical chemistryPesticide ResiduesAtmospheric-pressure chemical ionizationGeneral ChemistryPesticideBeesMass spectrometrySensitivity and SpecificityMass Spectrometrychemistry.chemical_compoundParathionOrganophosphorus CompoundschemistryAnimalsSelected ion monitoringGeneral Agricultural and Biological SciencesChromatography LiquidJournal of agricultural and food chemistry
researchProduct

Analysis of thiabendazole and procymidone in fruits and vegetables by capillary electrophoresis–electrospray mass spectrometry

2002

Abstract A capillary electrophoresis–mass spectrometry method for determining procymidone and thiabendazole in apples, grapes, oranges, pears, strawberries and tomatoes is described. Separation is achieved using a buffer of formic acid–ammonium formate at pH 3.5 with 2% of methanol. Fungicide residues present in the sample are preconcentrated by both solid-phase extraction and injection of large sample volumes into the capillary by a stacking technique, to obtain lower detection limits. Ionization is performed at atmospheric pressure in an electrospray type source and detection is carried out using positive ionization and selected ion monitoring modes. The quantitation limits are 0.005 and …

Detection limitSpectrometry Mass Electrospray IonizationElectrosprayChromatographyOrganic ChemistryPesticide ResiduesElectrophoresis CapillaryGeneral MedicineMass spectrometrySensitivity and SpecificityBiochemistryFungicides IndustrialAnalytical ChemistryBridged Bicyclo Compoundschemistry.chemical_compoundCapillary electrophoresischemistryFruitThiabendazoleVegetablesSample preparationSelected ion monitoringSolid phase extractionProcymidoneJournal of Chromatography A
researchProduct

The PAH composition of surface sediments from Stagnone coastal lagoon, Marsala (Italy)

2006

Abstract This paper examines the presence, distribution, nature and sources of 22 Aromatic Hydrocarbons (PAHs), which are important environmentally and toxicologically, in sediments from the Stagnone coastal lagoon at Marsala (Italy). Analysis was performed by gas chromatography/mass spectrometry (GC/MS) with selected ion monitoring (SIM). The total concentration of polycyclic aromatic hydrocarbons ranged from 72 to 18381 μg/kg of dry matrix. The relative standard deviation (RSD) of the replicates on the concentrations of individual compounds ranged from 5% to 20%. The accuracy of method was estimated by analyzing “blank” samples added of known quantities of analytes and the recover percent…

Detection limitchemistry.chemical_classificationStagnoneGas-mass analysisChemistryPAHGeneral ChemistryContaminationCoastal lagoonMarsalaOceanographyMass spectrometryMatrix (chemical analysis)PAHsCoastal lagoon; Environmental chemistry; Marsala; PAHs; StagnoneEnvironmental chemistryextractionEnvironmental ChemistrySeawaterSelected ion monitoringOrganic matterGas chromatographyMarine sedimentWater Science and TechnologyMarine Chemistry
researchProduct

Analysis of carbamate and phenylurea pesticide residues in fruit juices by solid-phase microextraction and liquid chromatography–mass spectrometry

2007

A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extrac…

ElectrosprayChromatographyChemistryPhenylurea CompoundsElectrospray ionizationOrganic ChemistrySelected reaction monitoringPesticide ResiduesGeneral MedicineSolid-phase microextractionMass spectrometryBiochemistryHigh-performance liquid chromatographyMass SpectrometryAnalytical ChemistryBeveragesLiquid chromatography–mass spectrometrySelected ion monitoringCarbamatesChromatography High Pressure LiquidJournal of Chromatography A
researchProduct